Kissing Stent Mri Safety Recipes

facebook share image   twitter share image   pinterest share image   E-Mail share image

More about "kissing stent mri safety recipes"

THE RESULTS OF SELF-EXPANDABLE KISSING STENTS IN AORTIC BIFURCATION
Web Mar 31, 2015 Materials and Methods: We reviewed medical records of the patients treated with a kissing stent retrospectively from January 2007 to December 2012. The primary …
From ncbi.nlm.nih.gov
Author Jae Young Moon, Hong Pil Hwang, Hyo Sung Kwak, Young Min Han, Hee Chul Yu
DOI 10.5758/vsi.2015.31.1.15
Publish Year 2015
Publication Vasc Specialist Int. 2015 Mar; 31(1)
See details


REVIEW OF SAFETY REPORTS OF CARDIAC MR-IMAGING IN PATIENTS WITH ...
Web ABSTRACT. Background: Aim of this study was to review current literature and data regarding the effects of MRI-examination post stent implantation on re-occlusion rates.. …
From tandfonline.com
Author Christian David Schenk, Rolf Gebker, Alexander Berger, Burkert Pieske, Christian Stehning, Sebastian...
Publish Year 2021
See details


DOUBLE KISSING CRUSH BIFURCATION STENTING: STEP-BY-STEP …
Web Jul 20, 2021 Introduction. Provisional stenting is the preferred and recommended stenting strategy for most coronary bifurcation lesions1,2; however, two-stent techniques are …
From ncbi.nlm.nih.gov
DOI 10.4244/EIJ-D-19-00721
Published 2021/07
Publication EuroIntervention. 2021 Jul; 17(4)
See details


TABLE OF CONTENTS - BOSTON SCIENTIFIC
Web A maximum whole body averaged specific absorption rate (SAR) of lower than 2.0 W/kg for a total active MR scan time (with RF exposure) of 15 minutes or less The WALLSTENT …
From bostonscientific.com
See details


SIMULTANEOUS KISSING STENTING: A VALUABLE TECHNIQUE FOR …
Web Additionally, less stent foreshortening on expansion is another advantage of open-cell stents because stent struts are not constrained to move along the long axis of the stent, …
From ncbi.nlm.nih.gov
See details


SAFETY OF MAGNETIC RESONANCE IMAGING IN PATIENTS WITH …
Web Safe MR imaging involves a careful initial patient screening, accurate determination of the permanent implanted or temporary cardiovascular device and its properties, a thoughtful …
From ahajournals.org
See details


MRI-INDUCED STENT DISLODGMENT SOON AFTER LEFT MAIN CORONARY …
Web Oct 1, 2013 Factors influencing the risk of MRI with metallic implants are (1) strength of the static magnetic field, (2) gradients of the magnetic field, (3) degree of ferromagnetism, (4) …
From ahajournals.org
See details


KISSING STENT MRI SAFETY RECIPES
Web 1. Instructions for Use (1) LifeStar™ Vascular Stent IFU. Please consult Instructions for Use for product indications for use, contraindications, warnings, precautions, complications, …
From tfrecipes.com
See details


SAFETY TOPIC/ARTICLE:
Web A patient with a with coronary artery stent (including a drug-eluting, non-drug eluting or bare metal version), including situations where there are two or more stents or two or more …
From mrisafety.com
See details


KISSING STENTS FOR TREATMENT OF COMPLEX AORTOILIAC DISEASE
Web The kissing stent technique has become popular for treatment of complex aortoiliac occlusive disease associated with stenoses, primarily at the level of the aortic bifurcation. …
From jvascsurg.org
See details


KISSING STENTS FOR TREATMENT OF COMPLEX AORTOILIAC DISEASE
Web Aug 1, 2003 By comparison, surgery is associated with 2-year patency rates of 92-94% (TASC). 12. These poor midterm results are comparable to the report of Brittenden et …
From sciencedirect.com
See details


FATE OF ASYMPTOMATIC LIMB AFTER KISSING STENTS IN AORTOILIAC …
Web Mar 31, 2022 Kissing stent deployment is a safe and effective strategy for the treatment of aortoiliac bifurcation disease. Unfavorable outcomes due to stenting in the asymptomatic …
From ncbi.nlm.nih.gov
See details


SAFETY OF MAGNETIC RESONANCE IMAGING IN PATIENTS WITH …
Web showed that MRI at 1.5 T can be performed within 1 to 14 days after stent implantation without any adverse clinical cardiac outcomes [30, 31]. More recent ex vivo studies, …
From annalsthoracicsurgery.org
See details


SHOULD KISSING BALLOON INFLATION AFTER MAIN VESSEL STENTING BE …
Web Jun 27, 2018 The KBI (kissing balloon inflation) technique is considered the default strategy for the two-stent approach in real world practice. Studies comparing KBI and No …
From journals.plos.org
See details


ICAST BALLOON-EXPANDABLE COVERED STENT FOR ILIAC …
Web Apr 25, 2019 Kissing stents and overlapping stents were permitted. Totally occluded lesions were allowed. ... In conclusion, the iCAST balloon-expandable covered stent was safe and effective for treatment of …
From jvir.org
See details


AORTOILIAC KISSING STENTS: LONG-TERM RESULTS AND ANALYSIS OF RISK ...
Web 10.1583/05-1708.1 Abstract Purpose: To present the early and long-term results of aortoiliac kissing stents implantation and evaluate the risk factors affecting patency. Methods: …
From pubmed.ncbi.nlm.nih.gov
See details


THE KISSING-STENT TECHNIQUE FOR TREATMENT OF DISTAL AORTIC STENOSIS …
Web Jul 1, 2012 The kissing-stent technique is a viable option for ensuring inferior mesenteric artery patency when treating distal aortic lesions by endovascular means in patients with …
From sciencedirect.com
See details


KISSING STENTS IN THE AORTIC BIFURCATION - PUBMED
Web PMID: 9778061 DOI: 10.1016/s0002-8703 (98)70005-5 Abstract Background: We report the first series of simultaneously delivered stents used to treat stenosis of the aortic …
From pubmed.ncbi.nlm.nih.gov
See details


IMPACT OF KISSING BALLOON IN PATIENTS TREATED WITH …
Web Importantly, these studies only included first- and second-generation drug-eluting stents, omitting the newer ultrathin stents. 12–14 In light of these limitations, we aimed to investigate the potential benefits of FKI in …
From ahajournals.org
See details


SAFETY TOPIC/ARTICLE:
Web MRI at 3-Tesla and Coils, Stents, Filters and Vascular Grafts. Different coils, stents, filters and vascular grafts have been evaluated at 3-Tesla. Of these implants, two displayed …
From mrisafety.com
See details


KISSING STENT TECHNIQUE FOR TASC C-D LESIONS OF COMMON
Web Feb 1, 2021 Bare metal (balloon or self-expandable) or covered stents were chosen in accordance with the plaque characteristics—that is bare-metal balloon-expandable in …
From sciencedirect.com
See details


CARDIAC STENTS AND MRI TEST, IS IT SAFE? - THE CANADIAN MEDICAL
Web Feb 24, 2023 One of the most effective ways to detect restenosis is through the use of magnetic resonance imaging (MRI). Cardiac stents are designed to open up blocked or …
From thecanadianmedical.ca
See details


THE LIST - MRI SAFETY
Web Safety Topic / Subject VeriFlex Stent VeriFlex Coronary Stent Boston Scientific Corporation, www.bostonscientific.com. 1.5,3: Conditional 5 More... Coils, Filters, Stents, and Grafts More... Veritas Collagen Matrix Synovis Surgical Innovations …
From mrisafety.com
See details