BLEND DOOR FAILURE TEST | DODGE RAM FORUM - DODGE TRUCK …
Web Nov 11, 2013 Springfield, MO. Ram Year. 2008 Dodge Ram. Engine. 4.7 liter 6-Speed Manual. If when you set the air to go to the floor only, and it only goes to the windshield defrost vent then it is probably your blend door. This is the problem I had. I ended up having it done for $531 parts and labor.
From ramforum.com
See details


BLEND DOOR MAKING NOISE? | DODGETALK FORUM
Web Sep 19, 2011 720 posts · Joined 2008. #3 · Sep 19, 2011. A/C recall was a flash for the A/C control head, nothing to do with the RRT for the blend door motor. If your under warranty take it in and the dealer will replace the motor. If your not under warranty buy the the motor for $35 and drop the lower glove box door and you will see the lower motor ...
From dodgetalk.com
See details


BLEND DOOR PROBLEMS | DODGE RAM FORUM - DODGE TRUCK FORUMS
Web Jun 18, 2011 5.7 / 5.7. The blend door is on the pass side behind the dash. If the door is broken your better off buying the updated system for the truck. The dash dosent have to come all the way out of the truck but does have to be unbolted and slid towards the back of the truck. We had to replace the setup in the 05.
From ramforum.com
See details


HVAC BLEND DOOR ISSUE | DODGE RAM FORUM - DODGE TRUCK …
Web Sep 26, 2021 There should be 2 actuators behind the radio bezel. 2 more on the passenger side, 1 by the fan, another up in back of the glove compartment. You can see the rod moving if the actuator is good. If you disconnect the rod from the actuator, then work the rod, you can easily Hear each door move if it is not broken.
From ramforum.com
See details


DODGE RAM BLEND DOOR HACK - YOUTUBE
Web Buddy didn't have any heat cause of the famous broken blend door. This is just something to give him heat for the winter.
From youtube.com
See details


DODGE RAM BLEND DOOR SYMPTOMS, : TROUBLESHOOT THE MOST …
Web Dodge ram blend door symptoms include weak airflow, inability to switch between hot and cold air, and strange noises. These issues indicate problems with the blend door, which directs the flow of air into the cabin of your vehicle. Neglecting these symptoms can lead to costly repairs down the line. The dodge ram is an.
From vehiclesnation.com
See details


BLEND DOOR PROBLEM - NEED SOME HELP | CUMMINS DIESEL FORUM
Web Apr 19, 2021 I have a 99 Dodge Ram 2500 and am having problems getting the blend door actuator to operate. I picked up a working blend door actuator and when I put 12 volts to the motor it operates and turns. I initially plugged it into the blend door plug hanging by the firewall and it worked when the key was on the ON position and the switch for defrost …
From cumminsforum.com
See details


RECIRCULATION HOOD | DODGE RAM FORUM
Web Sep 16, 2021 There was a blend door recall years ago. '09 Ram 1500 QC 4X4 Brilliant Black: DSP, CAI, Xpipe into 2.5" di/do Cherry Bomb Vortex, AirLift 1000 ... We’re the ultimate Dodge RAM forum to talk about the RAM 1500, 2500 and 3500 including the Cummins powered models. Full Forum Listing. Explore Our Forums.
From ramforumz.com
See details


DODGE RAM RECALLS IN CANADA | AUTO123
Web There are recalls for this vehicle! The list below shows all known recalls from Transport Canada's database. Click on the recall icon to view the details. DODGE RAM 2009 2010. DODGE RAM 2004 2010 ...
From auto123.com
See details


BLEND DOOR ISSUE? | DODGE RAM FORUM - DODGE TRUCK FORUMS
Web Feb 15, 2021 Just for your reference, Blend Doors control temperature and mode doors control what vent (s) get airflow. Pretty slow at work, so I've been randomly browsing the forums and have come across a few heater threads. That got me to thinking, that my heater doesn't blow very hot either! Hate when that happens.
From ramforum.com
See details


TECHNICAL SERVICE BULLETIN 20- LACK OF HEAT OR COOLING …
Web Procedure A: Remove The Driver Side Temperature Blend Door Actuator 1. Gently wipe the driver side temperature blend door actuator, cam, and cam follower attached to the climate control housing blend door to remove any debris and existing lubricant. NOTE: Do not remove the cam follower from the climate control housing blend door. It is critical to
From static.nhtsa.gov
See details


AFTERMARKET BLEND DOOR ACTUATOR AND OTHER HVAC ISSUES. - DODGE RAM FORUM
Web Apr 16, 2014 4 posts · Joined 2014. #1 · Apr 16, 2014. First off I want to thank everyone. When I first started having this problem this forum was a ton of help. Now to my problem, I had the notorious blend door actuator go bad. The one right behind the glove box. The OEM part number appears to be AA-113800-3041. I replaced it with a Dorman 604-005.
From ramforumz.com
See details


BLEND DOOR ACTUATORS | CUMMINS DIESEL FORUM
Web Dec 19, 2015 2010-2012 4th Gen Ram 6.7L Cummins. 2010-2012 Non-Powertrain ... They performed a recall and diagnosed the passenger blend door actuator as being the problem. I had given the dealer my case number from Chrysler. ... I had explained in the first email that I knew that the parts weren't covered but after doing research that with the recall k17 ...
From cumminsforum.com
See details


HEATER CLICKING LOUDLY - K17 RECALL | DODGE RAM FORUM
Web Mar 6, 2014 2009 Dodge Ram 1500 Sport I have searched high and low and haven't been able to find any similar problems as I am having. I see many 4th Gen Ram owners replacing the blend door actuator behind the center panel (radio area) but the actuator making the horrible clicking noise on my truck is directly behind the glove box. A couple …
From ramforumz.com
See details


ANYONE HAVE ISSUES WITH BLEND DOOR ON 4TH GEN?
Web Jan 14, 2015 464jet. 178 posts · Joined 2009. #2 · Jan 14, 2015. Yes there have been issues. A search should bring up several posts about 4 gen blend doors. Raminator157 Discussion starter. 278 posts · Joined 2007. #3 · Jan 22, 2015. Got some good news from my mechanic today.
From dodgetalk.com
See details


BLEND DOOR PROBLEM | DODGETALK FORUM
Web Aug 29, 2010 2. 2002Ram5.9 Discussion starter. 16 posts · Joined 2008. #1 · Aug 29, 2010 (Edited) I've been reading posts about the blend door problems for two day now, but I couldn't find any answers to my situation. I have a 2002 Sport with the climate control and have the typical driver cold - passenger hot problem. I also have a leaky heater core.
From dodgetalk.com
See details


DODGE RAM BLEND DOOR RECALL: WHY YOU NEED TO ACT NOW
Web The issue is often due to a malfunctioning blend door actuator or a broken blend door. This problem can result in irregular temperature output or no air flow at all. Dodge ram blend door recall was issued for the 2013-2017 model years to address this issue. Regular maintenance can also prevent blend door system failure.
From vehiclesnation.com
See details


DODGE RAM BLEND DOOR REPLACEMENT (QUICK & EASY PROCESS)
Web Jul 7, 2022 To replace an HVAC actuator of a blend door (for a Dodge Ram 2500), expect to pay between $150 and $500 on average. Between $400 and $500 is the average cost of labour. The replacement of an HVAC actuator (blend door) for a Dodge Ram 3500 can cost between $450 and $550. Estimates place the price of labour somewhere in the $400 …
From madisonrising.com
See details


DODGE RAM 2009-PRESENT: HOW TO REPLACE BLEND DOOR ACTUATOR
Web Jul 10, 2015 Step 2 – Replace blend door actuator. At this point you will be able to access both blend door actuators. Remove the wiring harness that plugs into the actuator, then the three screws that hold it into place. Set the new actuator (s) in place and install the three screws and the wiring harness. Figure 2.
From dodgeforum.com
See details


LOOK FOR VEHICLE RECALLS | OFFICIAL MOPAR® SITE
Web To schedule an appointment for a FREE Takata airbag inflator recall repair, please call 833-585-0144. Did you receive a Stop-Drive Advisory notice for your 2003 Dodge Ram Pickup Truck or 2005 – 2010 Chrysler or Dodge brand vehicle? Call 833-585-0144 – or contact your dealer – to discuss the best options for your immediate free repair ...
From mopar.com
See details


CUSTOMER SATISFACTION NOTIFICATION R62 REPROGRAM HVAC CONTROL …
Web Simply contact your Chrysler, Jeep, Dodge or RAM dealer right away to schedule a service appointment. Please bring this letter with you to your dealer. If you need help... If you have questions or concerns which your dealer is unable to resolve, please contact the FCA Group Recall Assistance Center at either fcarecalls.com or 1-800-853-1403.
From static.nhtsa.gov
See details


CHRYSLER RECALLS 142,000 RAM VEHICLES: HERE'S WHICH MODELS ARE …
Web Dec 5, 2023 The recall is for certain 2023 Ram 1500 Classic, Ram 3500 Classic, 3500 Cab Chassis as well as 2023-2024 Ram 2500, 4500/5500 Cab Chassis and Ram 3500 vehicles, according to the recall notice from ...
From msn.com
See details


BLEND DOOR ISSUES.. ACTUATOR NOT THE PROBLEM!!! - DODGE RAM FORUM
Web Dec 20, 2016 The blend door has a metal D shaft that the drive gear slides over. After I cut the hole I figured out the drive gear comes off by taking a thin screw driver at about the 11 oclock position from the arm and sliding it under the to release a push tab, then it slides off the shaft. I removed the obstruction and apoxy resin the side panel back in ...
From ramforumz.com
See details